light 
Vars | |
base_state | base description and icon_state |
---|---|
break_if_moved | break if moved, if false also makes it ignore if the wall its on breaks |
bulb_low_power_pow_mul | The multiplier for determining the light's power in low power mode |
cell | Cell reference |
fire_power | The Light power to use when working in fire alarm status |
fitting | String of the light type, used in descriptions and in examine |
flickering | Should we flicker? |
has_mock_cell | If TRUE, then cell is null, but one is pretending to exist. This is to defer emergency cell creation unless necessary, as it is very expensive. |
light_type | The type of light item |
low_power_mode | If true, the light is in low power mode |
major_emergency | If true, overrides lights to use emergency lighting |
nightshift_allowed | Set to FALSE to never let this light get switched to night mode. |
nightshift_brightness | Brightness of the nightshift light |
nightshift_enabled | Currently in night shift mode? |
nightshift_light_power | Alpha of the nightshift light |
no_low_power | If true, this light cannot ever be in low power mode |
on | Is the light on? |
overlay_icon | What overlay the light should use |
power_consumption_rate | Power usage - W per unit of luminosity |
start_with_cell | If true, this fixture generates a very weak cell at roundstart |
static_power_used | Amount of power used |
status | LIGHT_OK, _EMPTY, _BURNED or _BROKEN |
switchcount | Count of number of times switched on/off, this is used to calculate the probability the light burns out |
Procs | |
knock_down | All the effects that occur when a light falls off a wall that it was hung onto. |
Var Details
base_state 
base description and icon_state
break_if_moved 
break if moved, if false also makes it ignore if the wall its on breaks
bulb_low_power_pow_mul 
The multiplier for determining the light's power in low power mode
cell 
Cell reference
fire_power 
The Light power to use when working in fire alarm status
fitting 
String of the light type, used in descriptions and in examine
flickering 
Should we flicker?
has_mock_cell 
If TRUE, then cell is null, but one is pretending to exist. This is to defer emergency cell creation unless necessary, as it is very expensive.
light_type 
The type of light item
low_power_mode 
If true, the light is in low power mode
major_emergency 
If true, overrides lights to use emergency lighting
nightshift_allowed 
Set to FALSE to never let this light get switched to night mode.
nightshift_brightness 
Brightness of the nightshift light
nightshift_enabled 
Currently in night shift mode?
nightshift_light_power 
Alpha of the nightshift light
no_low_power 
If true, this light cannot ever be in low power mode
on 
Is the light on?
overlay_icon 
What overlay the light should use
power_consumption_rate 
Power usage - W per unit of luminosity
start_with_cell 
If true, this fixture generates a very weak cell at roundstart
static_power_used 
Amount of power used
status 
LIGHT_OK, _EMPTY, _BURNED or _BROKEN
switchcount 
Count of number of times switched on/off, this is used to calculate the probability the light burns out
Proc Details
knock_down